Annexair Package Cooling System

Air-Cooled (ACCU) or Air-Sourced Heat Pump (ASHF) Condensers

In the face of constantly increasing energy costs, Annexair responds by creating smart, energy-conscious designs. The traditional multi-stage compressor approach tries to improve comfort and generate savings, but without modulation, the opposite occurs. After analyzing many different cooling control techniques, the Annexair design team concluded that variable speed compressors are the best choice for our ACCU or ASHP units. Relying on a vast array of optimized sizes, Annexair ensures minimum energy use without compromise on comfort. Our packages are offered from as little as 5 tons and all the way to 300 tons with an optional air-sourced heat pump on certain sizes.

ACCU
Cooling only - Extended Condenser

59 - 300 TONS

Man in business attire standing with arms crossed next to a large industrial HVAC condenser unit with multiple cooling fans on top.

ACCU or ASHP

Cooling only or Heating & Cooling - Hanging Condenser

5 - 50 TONS

Large industrial air conditioning unit with multiple service doors and two large cooling fans on one side.

ASHP

Air Heat Pump - Extended Integrated Condenser

40 - 60 TONS*

Illustration of a laptop displaying a global map connected to three user profile icons, representing networked users or online collaboration.
Large industrial HVAC condenser unit with multiple access panels and four cooling fans on top.

ACCU

110 - 300 TONS

Man in business attire standing with arms crossed next to a large industrial HVAC condenser unit with multiple cooling fans on top.

*For Heat Pump models, Annexair is currently in development to increase the offer.

Microchannel condenser coils for improved performance

Entirely made of aluminum, these coils require less refrigerant as compared to conventional coils. Also, we offer an epoxy protective coating as an option.

Two rectangular microchannel coil heat exchangers with copper tubes, one silver and one black.
the inside of a building with a machine in it

Protective nylon screens as standard

To ensure a performing system, Annexair’s standard is to include a protective nylon screen for all condenser coils. In addition, this screen protects the unit from hail and helps prevent vandalism. Rain will automatically clean the screen but, should intensive washing be required, a tool-free VELCRO® attachment makes removing the screen fast and easy.

Water-Sourced Heat Pump Systems

Following in the same design of our Air-Cooled condensing series, each of our WSHP units utilizes the same engineering strategy: using head pressure control techniques that
includes building water flow modulation. Recently, our engineering team has conceived a new WSHP design that performs while remaining extremely rigid and robust. This high level of quality coupled with our construction rigidity easily distinguish Annexair WSHP from the competition.

Industrial refrigeration system with blue compressors, copper piping, and a black coiled insulated pipe on a metal frame.
10 - 45 TONS
Industrial refrigeration system with two blue compressors, copper piping, black coiled tubing, and a silver metal frame.
50 - 100 TONS
Industrial refrigeration system with three blue compressors, black cylindrical tanks, copper pipes and coiled black tubing mounted on a metal frame.
110 - 130 TONS
Black coiled insulated coaxial cable with copper connectors attached to two parallel copper bars.Close-up of a cut section of a coaxial cable showing a copper core with corrugated outer shielding inside a black insulating jacket.

High effectiveness heat exchanger

Annexair uses only coaxial tube-in-tube design for all our WSHP unit exchangers. All of these condenser coils operate very effectively as either refrigerant condensers or refrigerant evaporators when transferring heat with water. This makes them an ideal choice for water-source heat pumps. Water flows through the inner tube while refrigerant flows in the annulus between the inner and outer tubes.

The key to these coils' high performance lies in the convoluted multi-lead inner tube. The resulting tubes increase heat transfer surface area per unit length yet still permit full flow of both water and refrigerant around its entire periphery for improved performance. The net result is a highly effective, compact heat exchanger with superior anti-fouling features. Optimum heat transfer is also achieved with a counter-flow arrangement of water and refrigerant during condensation.